The Brewers' Handbook
Chapter 7

Cleaning and Sanitation

Methods of Application

Manually

Many craft brewers do not have the luxury of cleaning-in-place systems and have to manually clean and sanitize their equipment. The choice and concentration of detergents and sanitizers is limited in manual applications, given the risks to the user.  In addition, the temperature of the water is usually limited between 48 and 50ºC.

Clean-in-Place Systems

Clean-in-place (CIP) systems were developed by the dairy industry as a means of reducing the amount of labor need for cleaning and sanitizing operations. The simpler CIP units are usually made of at least one stainless steel tank, a centrifugal supply pump, stainless steel valves, a steam injection line, and tank spraying devices. Tank spraying devices can be simple-drilled, fixed spray balls, or rotating spray heads. Lighter soils usually can be dealt by using fixed spray balls, while rotating spray heads are better for heavier, more tenacious soils.

Click on the following topics for more information on brewery cleaning and sanitation.

Sponsored Sites
  • Hops
  • We service large and small brewing customers around the globe
  • www.barthhaasgroup.com
  • Malt and Ingredients
  • Brewers can count on Briess malts to deliver rich flavor and color to all their beers
  • www.briess.com
  • Beer Filtration Systems
  • A supplier of beer filtration equipment and media since 1989
  • www.abecfiltration.com
 
 
About   |   Advertise   |   Privacy Policy   |   Legal  |   Site Map   |    Contact Us