Chapter 12

Wort Cooling and Aeration

Wort Cooling Systems

From the physical point of view, cooling is an easy process. In practice, however, breweries can choose different ways of heat transfer using either a single-stage (chilled water only) or multiple-stage (ambient water, glycol) plate heat exchangers (see Figure 12.1). Wort enters the heat exchanger at between 96 and 99C and exits cooled to pitching temperature.

Single-Stage Cooling

The cooling operation can be achieved with a single-stage system using a glycol-jacketed cold-water tank to cool the wort (8).

Two-Stage Cooling

In a two-stage system the first stage utilizes water to remove the bulk of the heat, cooling the incoming wort to within 3C of fermentation temperature. In the second stage, the wort is cooled to the fermentation temperature by a secondary refrigerant (e.g., glycol, ammonia, etc).

Click on the following topics for more information on wort cooling and aeration.